All tests ok for central_feature_power_manager
This commit is contained in:
@@ -1,19 +1,15 @@
|
||||
# pylint: disable=protected-access, unused-argument, line-too-long
|
||||
""" Test the Central Power management """
|
||||
from unittest.mock import patch, call, AsyncMock, MagicMock, PropertyMock
|
||||
from unittest.mock import patch, AsyncMock, MagicMock, PropertyMock
|
||||
from datetime import datetime, timedelta
|
||||
import logging
|
||||
|
||||
from custom_components.versatile_thermostat.thermostat_switch import (
|
||||
ThermostatOverSwitch,
|
||||
)
|
||||
from custom_components.versatile_thermostat.feature_power_manager import (
|
||||
FeaturePowerManager,
|
||||
)
|
||||
from custom_components.versatile_thermostat.central_feature_power_manager import (
|
||||
CentralFeaturePowerManager,
|
||||
)
|
||||
from custom_components.versatile_thermostat.prop_algorithm import PropAlgorithm
|
||||
from .commons import * # pylint: disable=wildcard-import, unused-wildcard-import
|
||||
|
||||
logging.getLogger().setLevel(logging.DEBUG)
|
||||
@@ -194,17 +190,11 @@ async def test_central_power_manageer_find_vtherms(
|
||||
vtherms = []
|
||||
for vtherm_config in vtherm_configs:
|
||||
vtherm = MagicMock(spec=BaseThermostat)
|
||||
type(vtherm).name = PropertyMock(return_value=vtherm_config.get("name"))
|
||||
type(vtherm).is_on = PropertyMock(return_value=vtherm_config.get("is_on"))
|
||||
type(vtherm).current_temperature = PropertyMock(
|
||||
return_value=vtherm_config.get("current_temperature")
|
||||
)
|
||||
type(vtherm).target_temperature = PropertyMock(
|
||||
return_value=vtherm_config.get("target_temperature")
|
||||
)
|
||||
type(vtherm.power_manager).is_configured = PropertyMock(
|
||||
return_value=vtherm_config.get("is_configured")
|
||||
)
|
||||
vtherm.name = vtherm_config.get("name")
|
||||
vtherm.is_on = vtherm_config.get("is_on")
|
||||
vtherm.current_temperature = vtherm_config.get("current_temperature")
|
||||
vtherm.target_temperature = vtherm_config.get("target_temperature")
|
||||
vtherm.power_manager.is_configured = vtherm_config.get("is_configured")
|
||||
vtherms.append(vtherm)
|
||||
|
||||
with patch(
|
||||
@@ -371,6 +361,7 @@ async def test_central_power_manageer_find_vtherms(
|
||||
),
|
||||
],
|
||||
)
|
||||
# @pytest.mark.skip
|
||||
async def test_central_power_manageer_calculate_shedding(
|
||||
hass: HomeAssistant,
|
||||
current_power,
|
||||
@@ -414,16 +405,18 @@ async def test_central_power_manageer_calculate_shedding(
|
||||
|
||||
vtherms.append(vtherm)
|
||||
|
||||
type(central_power_manager).current_max_power = PropertyMock(
|
||||
return_value=current_max_power
|
||||
)
|
||||
type(central_power_manager).current_power = PropertyMock(return_value=current_power)
|
||||
type(central_power_manager).is_configured = PropertyMock(return_value=True)
|
||||
# type(central_power_manager).current_max_power = PropertyMock(
|
||||
# return_value=current_max_power
|
||||
# )
|
||||
# type(central_power_manager).current_power = PropertyMock(return_value=current_power)
|
||||
# type(central_power_manager).is_configured = PropertyMock(return_value=True)
|
||||
|
||||
with patch(
|
||||
"custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.find_all_vtherm_with_power_management_sorted_by_dtemp",
|
||||
return_value=vtherms,
|
||||
):
|
||||
# fmt:off
|
||||
with patch("custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.find_all_vtherm_with_power_management_sorted_by_dtemp", return_value=vtherms), \
|
||||
patch("custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.current_max_power", new_callable=PropertyMock, return_value=current_max_power), \
|
||||
patch("custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.current_power", new_callable=PropertyMock, return_value=current_power), \
|
||||
patch("custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.is_configured", new_callable=PropertyMock, return_value=True):
|
||||
# fmt:on
|
||||
|
||||
await central_power_manager.calculate_shedding()
|
||||
|
||||
@@ -431,7 +424,20 @@ async def test_central_power_manageer_calculate_shedding(
|
||||
assert registered_calls == expected_results
|
||||
|
||||
|
||||
async def test_central_power_manager_power_event(hass: HomeAssistant):
|
||||
@pytest.mark.parametrize(
|
||||
"dsecs, power, nb_call",
|
||||
[
|
||||
(0, 1000, 1),
|
||||
(61, 1000, 1),
|
||||
(59, 1000, 1),
|
||||
(0, None, 0),
|
||||
(0, STATE_UNAVAILABLE, 0),
|
||||
(0, STATE_UNKNOWN, 0),
|
||||
],
|
||||
)
|
||||
async def test_central_power_manager_power_event(
|
||||
hass: HomeAssistant, dsecs, power, nb_call
|
||||
):
|
||||
"""Tests the Power sensor event"""
|
||||
vtherm_api: VersatileThermostatAPI = MagicMock(spec=VersatileThermostatAPI)
|
||||
central_power_manager = CentralFeaturePowerManager(hass, vtherm_api)
|
||||
@@ -443,21 +449,162 @@ async def test_central_power_manager_power_event(hass: HomeAssistant):
|
||||
# 2. post_init
|
||||
central_power_manager.post_init(
|
||||
{
|
||||
CONF_POWER_SENSOR: power_entity_id,
|
||||
CONF_MAX_POWER_SENSOR: max_power_entity_id,
|
||||
CONF_USE_POWER_FEATURE: use_power_feature,
|
||||
CONF_POWER_SENSOR: "sensor.power_entity_id",
|
||||
CONF_MAX_POWER_SENSOR: "sensor.max_power_entity_id",
|
||||
CONF_USE_POWER_FEATURE: True,
|
||||
CONF_PRESET_POWER: 13,
|
||||
}
|
||||
)
|
||||
|
||||
assert central_power_manager.is_configured == True
|
||||
assert central_power_manager.is_configured is True
|
||||
assert central_power_manager.current_max_power is None
|
||||
assert central_power_manager.current_power is None
|
||||
assert central_power_manager.power_temperature == 13
|
||||
|
||||
# 3. start listening
|
||||
# 3. start listening (not really useful but don't eat bread)
|
||||
central_power_manager.start_listening()
|
||||
assert len(central_power_manager._active_listener) == 2
|
||||
|
||||
tz = get_tz(hass) # pylint: disable=invalid-name
|
||||
now: datetime = datetime.now(tz=tz)
|
||||
now: datetime = NowClass.get_now(hass)
|
||||
# vtherm_api._set_now(now) vtherm_api is a MagicMock
|
||||
vtherm_api.now = now
|
||||
|
||||
# 4. Call the _power_sensor_changed
|
||||
side_effects = SideEffects(
|
||||
{
|
||||
"sensor.power_entity_id": State("sensor.power_entity_id", power),
|
||||
"sensor.max_power_entity_id": State("sensor.max_power_entity_id", power),
|
||||
},
|
||||
State("unknown.entity_id", "unknown"),
|
||||
)
|
||||
# fmt:off
|
||||
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()), \
|
||||
patch("custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.calculate_shedding", new_callable=AsyncMock) as mock_calculate_shedding:
|
||||
# fmt:on
|
||||
# set a default value to see if it has been replaced
|
||||
central_power_manager._current_power = -999
|
||||
await central_power_manager._power_sensor_changed(event=Event(
|
||||
event_type=EVENT_STATE_CHANGED,
|
||||
data={
|
||||
"entity_id": "sensor.power_entity_id",
|
||||
"new_state": State("sensor.power_entity_id", power),
|
||||
"old_state": State("sensor.power_entity_id", STATE_UNAVAILABLE),
|
||||
}))
|
||||
|
||||
expected_power = power if isinstance(power, (int, float)) else -999
|
||||
assert central_power_manager.current_power == expected_power
|
||||
assert mock_calculate_shedding.call_count == nb_call
|
||||
|
||||
# Do another call x seconds later
|
||||
now = now + timedelta(seconds=dsecs)
|
||||
vtherm_api.now = now
|
||||
# fmt:off
|
||||
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()), \
|
||||
patch("custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.calculate_shedding", new_callable=AsyncMock) as mock_calculate_shedding:
|
||||
# fmt:on
|
||||
central_power_manager._current_power = -999
|
||||
|
||||
await central_power_manager._power_sensor_changed(event=Event(
|
||||
event_type=EVENT_STATE_CHANGED,
|
||||
data={
|
||||
"entity_id": "sensor.power_entity_id",
|
||||
"new_state": State("sensor.power_entity_id", power),
|
||||
"old_state": State("sensor.power_entity_id", STATE_UNAVAILABLE),
|
||||
}))
|
||||
|
||||
assert central_power_manager.current_power == expected_power
|
||||
assert mock_calculate_shedding.call_count == (nb_call if dsecs >= 60 else 0)
|
||||
|
||||
|
||||
@pytest.mark.parametrize(
|
||||
"dsecs, max_power, nb_call",
|
||||
[
|
||||
(0, 1000, 1),
|
||||
(61, 1000, 1),
|
||||
(59, 1000, 1),
|
||||
(0, None, 0),
|
||||
(0, STATE_UNAVAILABLE, 0),
|
||||
(0, STATE_UNKNOWN, 0),
|
||||
],
|
||||
)
|
||||
async def test_central_power_manager_max_power_event(
|
||||
hass: HomeAssistant, dsecs, max_power, nb_call
|
||||
):
|
||||
"""Tests the Power sensor event"""
|
||||
vtherm_api: VersatileThermostatAPI = MagicMock(spec=VersatileThermostatAPI)
|
||||
central_power_manager = CentralFeaturePowerManager(hass, vtherm_api)
|
||||
|
||||
assert central_power_manager.current_power is None
|
||||
assert central_power_manager.power_temperature is None
|
||||
assert central_power_manager.name == "centralPowerManager"
|
||||
|
||||
# 2. post_init
|
||||
central_power_manager.post_init(
|
||||
{
|
||||
CONF_POWER_SENSOR: "sensor.power_entity_id",
|
||||
CONF_MAX_POWER_SENSOR: "sensor.max_power_entity_id",
|
||||
CONF_USE_POWER_FEATURE: True,
|
||||
CONF_PRESET_POWER: 13,
|
||||
}
|
||||
)
|
||||
|
||||
assert central_power_manager.is_configured is True
|
||||
assert central_power_manager.current_max_power is None
|
||||
assert central_power_manager.current_power is None
|
||||
assert central_power_manager.power_temperature == 13
|
||||
|
||||
# 3. start listening (not really useful but don't eat bread)
|
||||
central_power_manager.start_listening()
|
||||
assert len(central_power_manager._active_listener) == 2
|
||||
|
||||
now: datetime = NowClass.get_now(hass)
|
||||
# vtherm_api._set_now(now) vtherm_api is a MagicMock
|
||||
vtherm_api.now = now
|
||||
|
||||
# 4. Call the _power_sensor_changed
|
||||
side_effects = SideEffects(
|
||||
{
|
||||
"sensor.power_entity_id": State("sensor.power_entity_id", max_power),
|
||||
"sensor.max_power_entity_id": State(
|
||||
"sensor.max_power_entity_id", max_power
|
||||
),
|
||||
},
|
||||
State("unknown.entity_id", "unknown"),
|
||||
)
|
||||
# fmt:off
|
||||
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()), \
|
||||
patch("custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.calculate_shedding", new_callable=AsyncMock) as mock_calculate_shedding:
|
||||
# fmt:on
|
||||
# set a default value to see if it has been replaced
|
||||
central_power_manager._current_max_power = -999
|
||||
await central_power_manager._power_sensor_changed(event=Event(
|
||||
event_type=EVENT_STATE_CHANGED,
|
||||
data={
|
||||
"entity_id": "sensor.max_power_entity_id",
|
||||
"new_state": State("sensor.max_power_entity_id", max_power),
|
||||
"old_state": State("sensor.max_power_entity_id", STATE_UNAVAILABLE),
|
||||
}))
|
||||
|
||||
expected_power = max_power if isinstance(max_power, (int, float)) else -999
|
||||
assert central_power_manager.current_max_power == expected_power
|
||||
assert mock_calculate_shedding.call_count == nb_call
|
||||
|
||||
# Do another call x seconds later
|
||||
now = now + timedelta(seconds=dsecs)
|
||||
vtherm_api.now = now
|
||||
# fmt:off
|
||||
with patch("homeassistant.core.StateMachine.get", side_effect=side_effects.get_side_effects()), \
|
||||
patch("custom_components.versatile_thermostat.central_feature_power_manager.CentralFeaturePowerManager.calculate_shedding", new_callable=AsyncMock) as mock_calculate_shedding:
|
||||
# fmt:on
|
||||
central_power_manager._current_max_power = -999
|
||||
|
||||
await central_power_manager._power_sensor_changed(event=Event(
|
||||
event_type=EVENT_STATE_CHANGED,
|
||||
data={
|
||||
"entity_id": "sensor.max_power_entity_id",
|
||||
"new_state": State("sensor.max_power_entity_id", max_power),
|
||||
"old_state": State("sensor.max_power_entity_id", STATE_UNAVAILABLE),
|
||||
}))
|
||||
|
||||
assert central_power_manager.current_max_power == expected_power
|
||||
assert mock_calculate_shedding.call_count == (nb_call if dsecs >= 60 else 0)
|
||||
|
||||
Reference in New Issue
Block a user