Test input in config_flow ok
This commit is contained in:
@@ -4,6 +4,7 @@
|
|||||||
from __future__ import annotations
|
from __future__ import annotations
|
||||||
|
|
||||||
from typing import Any
|
from typing import Any
|
||||||
|
import re
|
||||||
import logging
|
import logging
|
||||||
import copy
|
import copy
|
||||||
from collections.abc import Mapping # pylint: disable=import-error
|
from collections.abc import Mapping # pylint: disable=import-error
|
||||||
@@ -273,6 +274,34 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
|||||||
CONF_MIN_OPENING_DEGREES
|
CONF_MIN_OPENING_DEGREES
|
||||||
) from exc
|
) from exc
|
||||||
|
|
||||||
|
# Check the VSWITCH configuration. There should be the same number of vswitch_on (resp. vswitch_off) than the number of underlying entity
|
||||||
|
if self._infos.get(CONF_THERMOSTAT_TYPE) == CONF_THERMOSTAT_SWITCH and step_id == "type":
|
||||||
|
if not self.check_vswitch_configuration(data):
|
||||||
|
raise VirtualSwitchConfigurationIncorrect(CONF_VSWITCH_ON_CMD_LIST)
|
||||||
|
|
||||||
|
def check_vswitch_configuration(self, data) -> bool:
|
||||||
|
"""Check the Virtual switch configuration and return True if the configuration is correct"""
|
||||||
|
nb_under = len(data.get(CONF_UNDERLYING_LIST, []))
|
||||||
|
|
||||||
|
# check format of each command_on
|
||||||
|
for command in data.get(CONF_VSWITCH_ON_CMD_LIST, []) + data.get(CONF_VSWITCH_OFF_CMD_LIST, []):
|
||||||
|
pattern = r"^(?P<command>[a-zA-Z0-9_]+)(?:/(?P<argument>[a-zA-Z0-9_]+)(?::(?P<value>[a-zA-Z0-9_]+))?)?$"
|
||||||
|
if not re.match(pattern, command):
|
||||||
|
return False
|
||||||
|
|
||||||
|
nb_command_on = len(data.get(CONF_VSWITCH_ON_CMD_LIST, []))
|
||||||
|
nb_command_off = len(data.get(CONF_VSWITCH_OFF_CMD_LIST, []))
|
||||||
|
if (nb_command_on == nb_under or nb_command_on == 0) and (nb_command_off == nb_under or nb_command_off == 0):
|
||||||
|
# There is enough command_on and off
|
||||||
|
# Check if one under is not a switch (which have default command).
|
||||||
|
if any(
|
||||||
|
not thermostat_type.startswith(SWITCH_DOMAIN) and not thermostat_type.startswith(INPUT_BOOLEAN_DOMAIN) for thermostat_type in data.get(CONF_UNDERLYING_LIST, [])
|
||||||
|
):
|
||||||
|
if nb_command_on != nb_under or nb_command_off != nb_under:
|
||||||
|
return False
|
||||||
|
return True
|
||||||
|
return False
|
||||||
|
|
||||||
def check_config_complete(self, infos) -> bool:
|
def check_config_complete(self, infos) -> bool:
|
||||||
"""True if the config is now complete (ie all mandatory attributes are set)"""
|
"""True if the config is now complete (ie all mandatory attributes are set)"""
|
||||||
is_central_config = (
|
is_central_config = (
|
||||||
@@ -407,6 +436,8 @@ class VersatileThermostatBaseConfigFlow(FlowHandler):
|
|||||||
errors["base"] = "valve_regulation_nb_entities_incorrect"
|
errors["base"] = "valve_regulation_nb_entities_incorrect"
|
||||||
except ValveRegulationMinOpeningDegreesIncorrect as err:
|
except ValveRegulationMinOpeningDegreesIncorrect as err:
|
||||||
errors[str(err)] = "min_opening_degrees_format"
|
errors[str(err)] = "min_opening_degrees_format"
|
||||||
|
except VirtualSwitchConfigurationIncorrect as err:
|
||||||
|
errors["base"] = "vswitch_configuration_incorrect"
|
||||||
except Exception: # pylint: disable=broad-except
|
except Exception: # pylint: disable=broad-except
|
||||||
_LOGGER.exception("Unexpected exception")
|
_LOGGER.exception("Unexpected exception")
|
||||||
errors["base"] = "unknown"
|
errors["base"] = "unknown"
|
||||||
|
|||||||
@@ -565,6 +565,10 @@ class ValveRegulationMinOpeningDegreesIncorrect(HomeAssistantError):
|
|||||||
"""Error to indicate that the minimal opening degrees is not a list of int separated by coma"""
|
"""Error to indicate that the minimal opening degrees is not a list of int separated by coma"""
|
||||||
|
|
||||||
|
|
||||||
|
class VirtualSwitchConfigurationIncorrect(HomeAssistantError):
|
||||||
|
"""Error when a virtual switch is not configured correctly"""
|
||||||
|
|
||||||
|
|
||||||
class overrides: # pylint: disable=invalid-name
|
class overrides: # pylint: disable=invalid-name
|
||||||
"""An annotation to inform overrides"""
|
"""An annotation to inform overrides"""
|
||||||
|
|
||||||
|
|||||||
@@ -336,8 +336,9 @@
|
|||||||
"auto_regulation_use_device_temp": "Compenser la température interne du sous-jacent",
|
"auto_regulation_use_device_temp": "Compenser la température interne du sous-jacent",
|
||||||
"inverse_switch_command": "Inverser la commande",
|
"inverse_switch_command": "Inverser la commande",
|
||||||
"auto_fan_mode": " Auto ventilation mode",
|
"auto_fan_mode": " Auto ventilation mode",
|
||||||
"on_command_text": "Personnalisation des commandes",
|
"on_command_text": "Personnalisation des commandes d'allumage",
|
||||||
"vswitch_on_command": "Commande d'allumage (optionnel)",
|
"vswitch_on_command": "Commande d'allumage (optionnel)",
|
||||||
|
"off_command_text": "Personnalisation des commandes d'extinction",
|
||||||
"vswitch_off_command": "Commande d'extinction (optionnel)"
|
"vswitch_off_command": "Commande d'extinction (optionnel)"
|
||||||
},
|
},
|
||||||
"data_description": {
|
"data_description": {
|
||||||
@@ -351,9 +352,7 @@
|
|||||||
"auto_regulation_use_device_temp": "Compenser la temperature interne du sous-jacent pour accélérer l'auto-régulation",
|
"auto_regulation_use_device_temp": "Compenser la temperature interne du sous-jacent pour accélérer l'auto-régulation",
|
||||||
"inverse_switch_command": "Inverse la commande du switch pour une installation avec fil pilote et diode",
|
"inverse_switch_command": "Inverse la commande du switch pour une installation avec fil pilote et diode",
|
||||||
"auto_fan_mode": "Active la ventilation automatiquement en cas d'écart important",
|
"auto_fan_mode": "Active la ventilation automatiquement en cas d'écart important",
|
||||||
"on_command_text": "Pour les sous-jacents de type `select` ou `climate`",
|
"on_command_text": "Pour les sous-jacents de type `select` ou `climate`"
|
||||||
"vswitch_on_command": "Une liste de commande d'allumage au format: action:parameter. Exemple: select_option:comfort. Cf. README pour plus d'exmples",
|
|
||||||
"vswitch_off_command": "Une liste de commande d'extinction au format: action:parameter. Exemple: select_option:frost. Cf. README pour plus d'exmples"
|
|
||||||
}
|
}
|
||||||
},
|
},
|
||||||
"tpi": {
|
"tpi": {
|
||||||
@@ -498,7 +497,8 @@
|
|||||||
"no_central_config": "Vous ne pouvez pas cocher 'Utiliser la configuration centrale' car aucune configuration centrale n'a été trouvée. Vous devez créer un Versatile Thermostat de type 'Central Configuration' pour pouvoir l'utiliser.",
|
"no_central_config": "Vous ne pouvez pas cocher 'Utiliser la configuration centrale' car aucune configuration centrale n'a été trouvée. Vous devez créer un Versatile Thermostat de type 'Central Configuration' pour pouvoir l'utiliser.",
|
||||||
"service_configuration_format": "Mauvais format de la configuration du service",
|
"service_configuration_format": "Mauvais format de la configuration du service",
|
||||||
"valve_regulation_nb_entities_incorrect": "Le nombre d'entités pour la régulation par vanne doit être égal au nombre d'entité sous-jacentes",
|
"valve_regulation_nb_entities_incorrect": "Le nombre d'entités pour la régulation par vanne doit être égal au nombre d'entité sous-jacentes",
|
||||||
"min_opening_degrees_format": "Une liste d'entiers positifs séparés par des ',' est attendu. Exemple : 20, 25, 30"
|
"min_opening_degrees_format": "Une liste d'entiers positifs séparés par des ',' est attendu. Exemple : 20, 25, 30",
|
||||||
|
"vswitch_configuration_incorrect": "La configuration de la personnalisation des commandes est incorrecte. Elle est obligatoire pour les sous-jacents non switch et le format doit être 'service_name[/attribut:valeur]'. Plus d'informations dans le README."
|
||||||
},
|
},
|
||||||
"abort": {
|
"abort": {
|
||||||
"already_configured": "Le device est déjà configuré"
|
"already_configured": "Le device est déjà configuré"
|
||||||
|
|||||||
Reference in New Issue