Improve temperature logging (#825)
* Always log current temperature * Forcefully align each ata_sct_temperature_history data point to an integer multiple of the logging interval to prevent repeated data points Fixes #824
This commit is contained in:
@@ -23,9 +23,11 @@ func (sr *scrutinyRepository) SaveSmartTemperature(ctx context.Context, wwn stri
|
||||
continue
|
||||
}
|
||||
|
||||
minutesOffset := collectorSmartData.AtaSctTemperatureHistory.LoggingIntervalMinutes * int64(ndx) * 60
|
||||
intervalSec := collectorSmartData.AtaSctTemperatureHistory.LoggingIntervalMinutes * 60
|
||||
datapointTime := collectorSmartData.LocalTime.TimeT - int64(ndx) * intervalSec
|
||||
alignedDatapointTime := datapointTime - datapointTime % intervalSec
|
||||
smartTemp := measurements.SmartTemperature{
|
||||
Date: time.Unix(collectorSmartData.LocalTime.TimeT-minutesOffset, 0),
|
||||
Date: time.Unix(alignedDatapointTime, 0),
|
||||
Temp: temp,
|
||||
}
|
||||
|
||||
@@ -40,9 +42,10 @@ func (sr *scrutinyRepository) SaveSmartTemperature(ctx context.Context, wwn stri
|
||||
return err
|
||||
}
|
||||
}
|
||||
// also add the current temperature.
|
||||
} else {
|
||||
}
|
||||
|
||||
|
||||
// Even if ata_sct_temperature_history is present, also add current temperature. See #824
|
||||
smartTemp := measurements.SmartTemperature{
|
||||
Date: time.Unix(collectorSmartData.LocalTime.TimeT, 0),
|
||||
Temp: collectorSmartData.Temperature.Current,
|
||||
@@ -56,8 +59,6 @@ func (sr *scrutinyRepository) SaveSmartTemperature(ctx context.Context, wwn stri
|
||||
smartTemp.Date)
|
||||
return sr.influxWriteApi.WritePoint(ctx, p)
|
||||
}
|
||||
return nil
|
||||
}
|
||||
|
||||
func (sr *scrutinyRepository) GetSmartTemperatureHistory(ctx context.Context, durationKey string) (map[string][]measurements.SmartTemperature, error) {
|
||||
//we can get temp history for "week", "month", DURATION_KEY_YEAR, "forever"
|
||||
|
||||