# ONVIF Debugging Solution
|
||||
|
||||
## Problem
|
||||
|
||||
The diagnostic utility (`onvif-diagnostics`) logs only parsed JSON results. When XML parsing fails or responses are unexpected, you can't see the raw SOAP XML to debug the issue.
|
||||
|
||||
## Solution
|
||||
|
||||
The `onvif-diagnostics` utility now includes built-in XML capture functionality via the `-capture-xml` flag. This captures raw SOAP request/response XML and creates a compressed tar.gz archive.
|
||||
|
||||
## What Changed
|
||||
|
||||
### 1. Enhanced SOAP Client (`soap/soap.go`)
|
||||
|
||||
Added debug logging capability:
|
||||
|
||||
```go
|
||||
type Client struct {
|
||||
httpClient *http.Client
|
||||
username string
|
||||
password string
|
||||
debug bool // NEW
|
||||
logger func(format string, args ...interface{}) // NEW
|
||||
}
|
||||
|
||||
// New methods:
|
||||
func (c *Client) SetDebug(enabled bool, logger func(format string, args ...interface{}))
|
||||
func (c *Client) logDebug(format string, args ...interface{})
|
||||
```
|
||||
|
||||
The SOAP client now logs requests/responses when debug mode is enabled.
|
||||
|
||||
### 2. Integrated XML Capture in `onvif-diagnostics`
|
||||
|
||||
Location: `cmd/onvif-diagnostics/main.go`
|
||||
|
||||
Features:
|
||||
- Single command for both diagnostic report and XML capture
|
||||
- `-capture-xml` flag enables raw SOAP traffic capture
|
||||
- Creates compressed tar.gz archive with camera identification
|
||||
- Archive naming: `Manufacturer_Model_Firmware_xmlcapture_timestamp.tar.gz`
|
||||
- Saves to `camera-logs/` directory (same as diagnostic report)
|
||||
- Automatic cleanup of temporary files
|
||||
|
||||
## Usage
|
||||
|
||||
### Quick Start
|
||||
|
||||
```bash
|
||||
# Build the utility
|
||||
go build -o onvif-diagnostics ./cmd/onvif-diagnostics/
|
||||
|
||||
# Run with XML capture enabled
|
||||
./onvif-diagnostics \
|
||||
-endpoint "http://192.168.1.164/onvif/device_service" \
|
||||
-username "admin" \
|
||||
-password "password" \
|
||||
-capture-xml \
|
||||
-verbose
|
||||
```
|
||||
|
||||
This creates two files:
|
||||
- `Manufacturer_Model_Firmware_timestamp.json` - Diagnostic report
|
||||
- `Manufacturer_Model_Firmware_xmlcapture_timestamp.tar.gz` - Raw SOAP XML archive
|
||||
|
||||
### Without XML Capture (Faster)
|
||||
|
||||
```bash
|
||||
# Just diagnostic report
|
||||
./onvif-diagnostics \
|
||||
-endpoint "http://192.168.1.164/onvif/device_service" \
|
||||
-username "admin" \
|
||||
-password "password" \
|
||||
-verbose
|
||||
```
|
||||
|
||||
### Extract and Analyze XML
|
||||
|
||||
```bash
|
||||
# Extract the archive
|
||||
tar -xzf camera-logs/Camera_Model_xmlcapture_timestamp.tar.gz -C /tmp/xml-debug
|
||||
|
||||
# View files (now with operation names)
|
||||
ls /tmp/xml-debug/
|
||||
# capture_001_GetDeviceInformation.json
|
||||
# capture_001_GetDeviceInformation_request.xml
|
||||
# capture_001_GetDeviceInformation_response.xml
|
||||
# capture_002_GetSystemDateAndTime.json
|
||||
# ...
|
||||
```
|
||||
|
||||
## Workflow
|
||||
|
||||
### 1. Run Diagnostic with XML Capture
|
||||
|
||||
```bash
|
||||
./onvif-diagnostics \
|
||||
-endpoint "http://camera-ip/onvif/device_service" \
|
||||
-username "user" \
|
||||
-password "pass" \
|
||||
-capture-xml \
|
||||
-verbose
|
||||
```
|
||||
|
||||
This generates both:
|
||||
- JSON diagnostic report
|
||||
- tar.gz XML capture archive
|
||||
|
||||
### 2. Review Diagnostic Report
|
||||
|
||||
Check the JSON file for errors:
|
||||
```bash
|
||||
cat camera-logs/Camera_Model_Firmware_timestamp.json | jq '.errors'
|
||||
```
|
||||
|
||||
### 3. Analyze Raw XML (if needed)
|
||||
|
||||
Extract and inspect the XML archive:
|
||||
```bash
|
||||
tar -xzf camera-logs/Camera_Model_xmlcapture_timestamp.tar.gz -C /tmp/xml-debug
|
||||
```
|
||||
|
||||
### 3. Analyze Raw XML
|
||||
|
||||
```bash
|
||||
# Extract the archive
|
||||
tar -xzf camera-logs/Camera_Model_xmlcapture_timestamp.tar.gz -C /tmp/xml-debug
|
||||
|
||||
# View specific operation (now easier to find)
|
||||
cat /tmp/xml-debug/capture_*_GetCapabilities_response.xml
|
||||
|
||||
# Search for errors
|
||||
grep "Fault" /tmp/xml-debug/capture_*_response.xml
|
||||
|
||||
# Pretty-print (XML is already formatted with indentation)
|
||||
cat /tmp/xml-debug/capture_001_GetDeviceInformation_response.xml
|
||||
```
|
||||
|
||||
## Example: Debugging AXIS Q3626-VE Localhost Issue
|
||||
|
||||
### Problem (from diagnostic report)
|
||||
|
||||
```json
|
||||
{
|
||||
"operation": "GetProfiles",
|
||||
"error": "Post \"http://127.0.0.1/onvif/services\": EOF"
|
||||
}
|
||||
```
|
||||
|
||||
### Capture XML
|
||||
|
||||
```bash
|
||||
### Capture XML
|
||||
|
||||
```bash
|
||||
./onvif-diagnostics \
|
||||
-endpoint "http://192.168.1.164/onvif/device_service" \
|
||||
-username "admin" \
|
||||
-password "password" \
|
||||
-capture-xml \
|
||||
-verbose
|
||||
```
|
||||
|
||||
Result:
|
||||
- `camera-logs/AXIS_Q3626-VE_12.6.104_20251110-120000.json`
|
||||
- `camera-logs/AXIS_Q3626-VE_12.6.104_xmlcapture_20251110-120000.tar.gz`
|
||||
```
|
||||
|
||||
Result: `camera-logs/AXIS_Q3626-VE_12.6.104_xmlcapture_20251110-120000.tar.gz`
|
||||
|
||||
### Analyze Response
|
||||
|
||||
```bash
|
||||
tar -xzf camera-logs/AXIS_Q3626-VE_12.6.104_xmlcapture_20251110-120000.tar.gz
|
||||
cat capture_*_GetCapabilities_response.xml | grep XAddr
|
||||
```
|
||||
|
||||
Shows:
|
||||
|
||||
```xml
|
||||
<Media>
|
||||
<XAddr>http://127.0.0.1/onvif/services</XAddr>
|
||||
</Media>
|
||||
```
|
||||
|
||||
### Root Cause
|
||||
|
||||
Camera returns `127.0.0.1` instead of actual IP `192.168.1.164`, causing client to connect to localhost.
|
||||
|
||||
### Solution Required
|
||||
|
||||
Client needs to rewrite localhost addresses:
|
||||
|
||||
```go
|
||||
if strings.Contains(xAddr, "127.0.0.1") || strings.Contains(xAddr, "localhost") {
|
||||
// Replace with actual camera IP from original endpoint
|
||||
}
|
||||
```
|
||||
|
||||
## Example: Debugging Bosch Panoramic "Incomplete Configuration"
|
||||
|
||||
### Problem (from diagnostic report)
|
||||
|
||||
```json
|
||||
{
|
||||
"operation": "GetStreamURI[9]",
|
||||
"error": "ter:IncompleteConfiguration - Configuration not complete"
|
||||
}
|
||||
```
|
||||
|
||||
### Capture XML
|
||||
|
||||
```bash
|
||||
### Capture XML
|
||||
|
||||
```bash
|
||||
./onvif-diagnostics \
|
||||
-endpoint "http://192.168.2.24/onvif/device_service" \
|
||||
-username "service" \
|
||||
-password "Service.1234" \
|
||||
-capture-xml \
|
||||
-verbose
|
||||
```
|
||||
|
||||
Result:
|
||||
- `camera-logs/Bosch_FLEXIDOME_panoramic_5100i_9.00.0210_20251110.json`
|
||||
- `camera-logs/Bosch_FLEXIDOME_panoramic_5100i_9.00.0210_xmlcapture_20251110.tar.gz`
|
||||
```
|
||||
|
||||
### Analyze Response
|
||||
|
||||
```bash
|
||||
tar -xzf camera-logs/Bosch_FLEXIDOME_panoramic_5100i_*_xmlcapture_*.tar.gz
|
||||
# Look for GetStreamUri operation (easy to find by name)
|
||||
cat capture_*_GetStreamUri_response.xml
|
||||
```
|
||||
|
||||
Result:
|
||||
|
||||
```xml
|
||||
<SOAP-ENV:Fault>
|
||||
<SOAP-ENV:Code>
|
||||
<SOAP-ENV:Subcode>
|
||||
<SOAP-ENV:Value>ter:IncompleteConfiguration</SOAP-ENV:Value>
|
||||
</SOAP-ENV:Subcode>
|
||||
</SOAP-ENV:Code>
|
||||
<SOAP-ENV:Reason>
|
||||
<SOAP-ENV:Text>Configuration not complete</SOAP-ENV:Text>
|
||||
</SOAP-ENV:Reason>
|
||||
</SOAP-ENV:Fault>
|
||||
```
|
||||
|
||||
### Root Cause
|
||||
|
||||
Profile 9 has `VideoEncoderConfiguration: null` in the profiles response. Can't get stream URI for profile without video encoder.
|
||||
|
||||
### Solution
|
||||
|
||||
Skip GetStreamURI for profiles without VideoEncoderConfiguration:
|
||||
|
||||
```go
|
||||
if profile.VideoEncoderConfiguration == nil {
|
||||
// Skip - this is audio-only or metadata-only profile
|
||||
continue
|
||||
}
|
||||
```
|
||||
|
||||
## Files Created
|
||||
|
||||
### SOAP Client Enhancement
|
||||
- `soap/soap.go` - Added debug logging capability
|
||||
|
||||
### Diagnostic Utility Enhancement
|
||||
- `cmd/onvif-diagnostics/main.go` - Added XML capture functionality with `-capture-xml` flag
|
||||
|
||||
## Output Organization
|
||||
|
||||
All debugging files are saved to the same `camera-logs/` directory:
|
||||
|
||||
```
|
||||
camera-logs/
|
||||
├── Bosch_FLEXIDOME_indoor_5100i_IR_8.71.0066_20251107-193656.json # Diagnostic report
|
||||
├── Bosch_FLEXIDOME_indoor_5100i_IR_8.71.0066_xmlcapture_20251110.tar.gz # XML capture archive
|
||||
├── AXIS_Q3626-VE_12.6.104_20251108-212157.json
|
||||
├── AXIS_Q3626-VE_12.6.104_xmlcapture_20251108-213000.tar.gz
|
||||
└── Bosch_FLEXIDOME_panoramic_5100i_9.00.0210_20251107-195636.json
|
||||
```
|
||||
|
||||
### Archive Contents
|
||||
|
||||
Each tar.gz archive contains the captured XML files with descriptive operation names:
|
||||
|
||||
```bash
|
||||
$ tar -tzf camera-logs/Bosch_FLEXIDOME_indoor_5100i_IR_*_xmlcapture_*.tar.gz
|
||||
capture_001_GetDeviceInformation.json
|
||||
capture_001_GetDeviceInformation_request.xml
|
||||
capture_001_GetDeviceInformation_response.xml
|
||||
capture_002_GetSystemDateAndTime.json
|
||||
capture_002_GetSystemDateAndTime_request.xml
|
||||
capture_002_GetSystemDateAndTime_response.xml
|
||||
capture_003_GetCapabilities.json
|
||||
capture_003_GetCapabilities_request.xml
|
||||
capture_003_GetCapabilities_response.xml
|
||||
...
|
||||
```
|
||||
|
||||
Each file is named with both a sequence number and the SOAP operation name for easy identification.
|
||||
|
||||
## Benefits
|
||||
|
||||
1. **Complete Visibility**: See exact SOAP XML sent/received
|
||||
2. **Namespace Debugging**: Identify namespace mismatches
|
||||
3. **Fault Analysis**: See detailed SOAP fault information
|
||||
4. **Comparison**: Compare working vs failing cameras
|
||||
5. **Easy Sharing**: Compressed archives (< 10KB) easy to share via email
|
||||
6. **Organized**: All camera logs in one directory with consistent naming
|
||||
7. **Privacy**: Review and sanitize XML before sharing archives
|
||||
|
||||
## Next Steps
|
||||
|
||||
When you encounter errors in the diagnostic report:
|
||||
|
||||
1. ✅ Run `onvif-diagnostics` to identify which operations fail
|
||||
2. ✅ Re-run with `-capture-xml` flag to capture raw XML
|
||||
3. ✅ Extract and analyze the tar.gz archive
|
||||
4. ✅ Share both files (JSON report + tar.gz archive) for debugging assistance
|
||||
|
||||
## Command-Line Flags
|
||||
|
||||
```
|
||||
-endpoint string
|
||||
ONVIF device endpoint (required)
|
||||
|
||||
-username string
|
||||
Username for authentication (required)
|
||||
|
||||
-password string
|
||||
Password for authentication (required)
|
||||
|
||||
-output string
|
||||
Output directory (default: "./camera-logs")
|
||||
|
||||
-timeout int
|
||||
Request timeout in seconds (default: 30)
|
||||
|
||||
-verbose
|
||||
Enable verbose output
|
||||
|
||||
-capture-xml
|
||||
Capture raw SOAP XML traffic and create tar.gz archive
|
||||
```
|
||||
|
||||
## Output Structure
|
||||
|
||||
### Before (separate files):
|
||||
```
|
||||
xml-captures/
|
||||
└── 20251110-095000/
|
||||
├── capture_001.json
|
||||
├── capture_001_request.xml
|
||||
├── capture_001_response.xml
|
||||
└── ...
|
||||
```
|
||||
|
||||
### Now (compressed archives):
|
||||
```
|
||||
camera-logs/
|
||||
├── Bosch_FLEXIDOME_indoor_5100i_IR_8.71.0066_20251107-193656.json
|
||||
├── Bosch_FLEXIDOME_indoor_5100i_IR_8.71.0066_xmlcapture_20251110-115830.tar.gz (5KB)
|
||||
├── AXIS_Q3626-VE_12.6.104_20251108-212157.json
|
||||
└── AXIS_Q3626-VE_12.6.104_xmlcapture_20251110-120000.tar.gz (3KB)
|
||||
```
|
||||
|
||||
## Tips
|
||||
|
||||
- Use `-operation` to test specific failing operations
|
||||
- Check response XML for `<Fault>` elements
|
||||
- Compare namespace prefixes (tds, trt, tt, etc.)
|
||||
- Look for XAddr values in capabilities response
|
||||
- Verify authentication headers in request XML
|
||||