from homeassistant.const import Platform
from . import const, BaseDevice, EntityMigration, MigrationAction
from ..entities import BaseSensorEntity, BaseNumberEntity, BaseSwitchEntity, BaseSelectEntity
from ..mqtt.ecoflow_mqtt import EcoflowMQTTClient
from ..number import ChargingPowerEntity, MaxBatteryLevelEntity, MinBatteryLevelEntity
from ..select import DictSelectEntity, TimeoutDictSelectEntity
from ..sensor import LevelSensorEntity, RemainSensorEntity, TempSensorEntity, \
CyclesSensorEntity, InWattsSensorEntity, OutWattsSensorEntity, VoltSensorEntity, StatusSensorEntity, \
MilliVoltSensorEntity, InMilliVoltSensorEntity, OutMilliVoltSensorEntity, ChargingStateSensorEntity, \
CapacitySensorEntity
from ..switch import EnabledEntity
class River2(BaseDevice):
def charging_power_step(self) -> int:
return 50
def sensors(self, client: EcoflowMQTTClient) -> list[BaseSensorEntity]:
return [
LevelSensorEntity(client, "bms_bmsStatus.soc", const.MAIN_BATTERY_LEVEL)
.attr("bms_bmsStatus.designCap", const.ATTR_DESIGN_CAPACITY, 0)
.attr("bms_bmsStatus.fullCap", const.ATTR_FULL_CAPACITY, 0)
.attr("bms_bmsStatus.remainCap", const.ATTR_REMAIN_CAPACITY, 0),
CapacitySensorEntity(client, "bms_bmsStatus.designCap", const.MAIN_DESIGN_CAPACITY, False),
CapacitySensorEntity(client, "bms_bmsStatus.fullCap", const.MAIN_FULL_CAPACITY, False),
CapacitySensorEntity(client, "bms_bmsStatus.remainCap", const.MAIN_REMAIN_CAPACITY, False),
LevelSensorEntity(client, "bms_bmsStatus.soh", const.SOH),
LevelSensorEntity(client, "bms_emsStatus.lcdShowSoc", const.COMBINED_BATTERY_LEVEL),
ChargingStateSensorEntity(client, "bms_emsStatus.chgState", const.BATTERY_CHARGING_STATE),
InWattsSensorEntity(client, "pd.wattsInSum", const.TOTAL_IN_POWER),
OutWattsSensorEntity(client, "pd.wattsOutSum", const.TOTAL_OUT_POWER),
InWattsSensorEntity(client, "inv.inputWatts", const.AC_IN_POWER),
OutWattsSensorEntity(client, "inv.outputWatts", const.AC_OUT_POWER),
InMilliVoltSensorEntity(client, "inv.acInVol", const.AC_IN_VOLT),
OutMilliVoltSensorEntity(client, "inv.invOutVol", const.AC_OUT_VOLT),
InWattsSensorEntity(client, "pd.typecChaWatts", const.TYPE_C_IN_POWER),
InWattsSensorEntity(client, "mppt.inWatts", const.SOLAR_IN_POWER),
OutWattsSensorEntity(client, "pd.carWatts", const.DC_OUT_POWER),
OutWattsSensorEntity(client, "pd.typec1Watts", const.TYPEC_1_OUT_POWER),
# both USB-A Ports (the small RIVER 2 has only two) are being summarized under "pd.usb1Watts" - https://github.com/tolwi/hassio-ecoflow-cloud/issues/12#issuecomment-1432837393
OutWattsSensorEntity(client, "pd.usb1Watts", const.USB_OUT_POWER),
RemainSensorEntity(client, "bms_emsStatus.chgRemainTime", const.CHARGE_REMAINING_TIME),
RemainSensorEntity(client, "bms_emsStatus.dsgRemainTime", const.DISCHARGE_REMAINING_TIME),
TempSensorEntity(client, "inv.outTemp", "Inv Out Temperature"),
CyclesSensorEntity(client, "bms_bmsStatus.cycles", const.CYCLES),
TempSensorEntity(client, "bms_bmsStatus.temp", const.BATTERY_TEMP)
.attr("bms_bmsStatus.minCellTemp", const.ATTR_MIN_CELL_TEMP, 0)
.attr("bms_bmsStatus.maxCellTemp", const.ATTR_MAX_CELL_TEMP, 0),
TempSensorEntity(client, "bms_bmsStatus.minCellTemp", const.MIN_CELL_TEMP, False),
TempSensorEntity(client, "bms_bmsStatus.maxCellTemp", const.MAX_CELL_TEMP, False),
VoltSensorEntity(client, "bms_bmsStatus.vol", const.BATTERY_VOLT, False)
.attr("bms_bmsStatus.minCellVol", const.ATTR_MIN_CELL_VOLT, 0)
.attr("bms_bmsStatus.maxCellVol", const.ATTR_MAX_CELL_VOLT, 0),
MilliVoltSensorEntity(client, "bms_bmsStatus.minCellVol", const.MIN_CELL_VOLT, False),
MilliVoltSensorEntity(client, "bms_bmsStatus.maxCellVol", const.MAX_CELL_VOLT, False),
# FanSensorEntity(client, "bms_emsStatus.fanLevel", "Fan Level"),
StatusSensorEntity(client),
]
def numbers(self, client: EcoflowMQTTClient) -> list[BaseNumberEntity]:
return [
MaxBatteryLevelEntity(client, "bms_emsStatus.maxChargeSoc", const.MAX_CHARGE_LEVEL, 50, 100,
lambda value: {"moduleType": 2, "operateType": "upsConfig",
"params": {"maxChgSoc": int(value)}}),
MinBatteryLevelEntity(client, "bms_emsStatus.minDsgSoc", const.MIN_DISCHARGE_LEVEL, 0, 30,
lambda value: {"moduleType": 2, "operateType": "dsgCfg",
"params": {"minDsgSoc": int(value)}}),
ChargingPowerEntity(client, "mppt.cfgChgWatts", const.AC_CHARGING_POWER, 100, 360,
lambda value: {"moduleType": 5, "operateType": "acChgCfg",
"params": {"chgWatts": int(value), "chgPauseFlag": 255}}),
]
def switches(self, client: EcoflowMQTTClient) -> list[BaseSwitchEntity]:
return [
EnabledEntity(client, "mppt.cfgAcEnabled", const.AC_ENABLED,
lambda value: {"moduleType": 5, "operateType": "acOutCfg",
"params": {"enabled": value, "out_voltage": -1, "out_freq": 255,
"xboost": 255}}),
EnabledEntity(client, "mppt.cfgAcXboost", const.XBOOST_ENABLED,
lambda value: {"moduleType": 5, "operateType": "acOutCfg",
"params": {"enabled": 255, "out_voltage": -1, "out_freq": 255,
"xboost": value}}),
EnabledEntity(client, "pd.carState", const.DC_ENABLED,
lambda value: {"moduleType": 5, "operateType": "mpptCar", "params": {"enabled": value}})
]
def selects(self, client: EcoflowMQTTClient) -> list[BaseSelectEntity]:
return [
DictSelectEntity(client, "mppt.dcChgCurrent", const.DC_CHARGE_CURRENT, const.DC_CHARGE_CURRENT_OPTIONS,
lambda value: {"moduleType": 5, "operateType": "dcChgCfg",
"params": {"dcChgCfg": value}}),
DictSelectEntity(client, "mppt.cfgChgType", const.DC_MODE, const.DC_MODE_OPTIONS,
lambda value: {"moduleType": 5, "operateType": "chaType",
"params": {"chaType": value}}),
TimeoutDictSelectEntity(client, "mppt.scrStandbyMin", const.SCREEN_TIMEOUT, const.SCREEN_TIMEOUT_OPTIONS,
lambda value: {"moduleType": 5, "operateType": "lcdCfg",
"params": {"brighLevel": 255, "delayOff": value}}),
TimeoutDictSelectEntity(client, "mppt.powStandbyMin", const.UNIT_TIMEOUT, const.UNIT_TIMEOUT_OPTIONS,
lambda value: {"moduleType": 5, "operateType": "standby",
"params": {"standbyMins": value}}),
TimeoutDictSelectEntity(client, "mppt.acStandbyMins", const.AC_TIMEOUT, const.AC_TIMEOUT_OPTIONS,
lambda value: {"moduleType": 5, "operateType": "acStandby",
"params": {"standbyMins": value}})
]
def migrate(self, version) -> list[EntityMigration]:
if version == 2:
return [
EntityMigration("pd.soc", Platform.SENSOR, MigrationAction.REMOVE),
]
return []